Removal of COD in Purified Terephthalic Acid (PTA) Effluent with Coagulation, Aqueous Oxidation and High Porosity Membrane

COD Removal in PTA Effluent

  • Niaz Ahmed Memon PCSIR Laboratories Complex, Shahrah-e-Dr. Salimuzzaman Siddiqui, Karachi-75280, Pakistan
  • Nisar Ahmed Leather Research Centre, PCSIR, D-102, S.I.T.E., South Avenue, Karachi-75700, Pakistan
  • Sarwat Ismail PCSIR Laboratories Complex, Shahrah-e-Dr. Salimuzzaman Siddiqui, Karachi-75280, Pakistan
  • Nusrat Jalbani PCSIR Laboratories Complex, Shahrah-e-Dr. Salimuzzaman Siddiqui, Karachi-75280, Pakistan
  • Uzma Asghar PCSIR Laboratories Complex, Shahrah-e-Dr. Salimuzzaman Siddiqui, Karachi-75280, Pakistan
  • Tahira Ayaz Leather Research Centre, PCSIR, D-102, S.I.T.E., South Avenue, Karachi-75700, Pakistan
  • Razia Begum PCSIR Laboratories Complex, Shahrah-e-Dr. Salimuzzaman Siddiqui, Karachi-75280, Pakistan
Keywords: COD reduction, coagulation, active oxidation, ceramic membrane, purified terephthalic acid

Abstract

Present study was focused on purified terephthalic acid (PTA) industry wastewater treatment located at Port Qasim, Karachi. PTA wastewater containing high COD (100000 to 150000 mg/L) was treated with coagulate ferrous ion and then was oxidized independently with aqueous hydrogen peroxide using different doses at 45 °C for 1h. The resulting wastewater was passed through RO plant equipped with high porosity bio-ceramic membrane. It was observed that coagulation and oxidation processes have potential to reduce 87.9% COD but complete reduction up to 99.8% was achieved after passing the effluents from high RO plant equipped with high porosity ceramic membrane.

Published
2016-10-27